Section 5: Venting Systems; Full Reline With Outside Air-Horizontal - Quadra-Fire SANTAFEI-MBK Owner's Manual

Santa fe pellet insert
Hide thumbs Also See for SANTAFEI-MBK:
Table of Contents

Advertisement

Santa Fe Pellet Insert
5
Venting Systems
A. Full Reline With Outside Air - Horizontal
CAUTION
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Figure 15.1
Figure 15.1
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365.
Page 14
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insu-
lation such as fiberglass, mineral
wool or ceramic.
Do not use high temperature
caulking materials to seal any
edge to prevent furture service-
ability.
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be a minimum 6 inch
(152mm) UL103 HT.
Outside Air through Rear
Wall (Horizontal)
NOTE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
7019-221D
WARNING
January 21, 2013
R