Connection - Platinum 7000 R3 Installation And User Manual

Hide thumbs Also See for 7000 R3:
Table of Contents

Advertisement

Installation

3.4 Connection

3.4.1
Preparatory work
5
3.4.2
Connect the AC voltage
DANGER
Risk of death due to high AC voltage!
f Switch off the mains voltage supply (AC side) before connecting the
inverter (safety device).
f Make sure that the central isolation device can be accessed freely.
f Only connect the inverter to TN or TT networks (see IEC 60364-1)
with 230 V.
f Observe max. fuse protection permitted on the AC voltage side; see
"Technical data" on page 44.
f Make the AC voltage connection with a circuit breaker.
PLATINUM® recommends a type C miniature circuit breaker.
f If an external residual current protective device is required,
PLATINUM® recommends using a residual current protective device
(RCD) of type A.
12
1. Move the switch knob of the DC
isolator to position 0.
2. Loosen 6 screws on service cover.
3. To remove the service cover, push the
nose (5) forwards on the side of the
handle recess.
Installation and user guide PLATINUM® Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3