Page: 41
Service Guide OKIPAGE4w
Chapter 3 Parts Replacement
Fuser Assy
(1) Remove the upper cover assy. (See Upper Cover Assy in this Chapter).
(2) Remove the high-voltage power supply board. (See High-Voltage Power Supply Board in this
Chapter).
(3) Remove two screws 1, disconnect connector 2, and remove heat assy 3.
Note: Do not disconnect lamp ground screw on left side of fuser.