Device
Resident RAM
configuration error
Check Error
Device
EEPROM Check
configuration error
Error
Device
Option RAM
configuration error
Check Error
Device
Fuser Error
configuration error
Device
Thermistor Error
configuration error
Device
Thermistor Open
configuration error
Check Error
Device
Thermistor Short
configuration error
Check Error
Device
Watch Dog
configuration error
Timeout Error
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner
Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
60 30
An error occurred during
resident RAM check.
60 40
An error occurred during
EEPROM check.
60 60
An error occurred during
option RAM check.
60 80
A heater timeout error
occurred.
60 90
A thermistor error
occurred.
60 91
The thermistor is open.
60 92
A thermistor short
occurred.
60 00
A watchdog timeout
occurred.
Replace the main
control board.
(When replacing the
main control board,
also adjust
EEPROM data).
Replace the main
control board.
(When replacing the
main control board,
also adjust
EEPROM data).
Check the
connection of the
Option RAM PC
board. If the option
RAM PC board is
faulty, replace it.
See Fuser Assy
Error
Replace the heat
Assy.
Replace the heat
Assy.
Replace the heat
Assy.
To clear the error
display, turn on the
power supply again.
Replace the main
control board.

Advertisement