Hopping Shaft Assy - Oki Okipage4w Service Manual

Led page printer
Hide thumbs Also See for Okipage4w:
Table of Contents

Advertisement

Page: 45
Service Guide OKIPAGE4w
Chapter 3 Parts Replacement

Hopping Shaft Assy

(1) Remove the upper cover assy. (See Upper Cover Assy in this Chapter).
(2) Remove the high-voltage power supply board. (See High-Voltage Power Supply Board in this
Chapter).
(3) Remove the base frame. (See Separator Guide in this Chapter).
(4) Remove the paper holder assy. (See Paper Holder in this Chapter).
(5) Remove the sheet guide. (See Sepator Guide in this Chapter).
(6) Remove side plate M. (See Side Plate M and Idle Gear in this Chapter).
(7) Raise up roller holder 3, slide hopping shaft assy 1, and remove roller holder 3 and hopping roller 4.
(Knock pin 5 also comes off at the same time. Take care not to lose it.)
(8) Draw out hopping shaft assy 1 to the right and remove magnet H6.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner
Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)