Final Steps; Remove The Opi; Check For Safety Labels And Signs; Subsequent Steps - Hughes AN6-098P Installation Manual

.98 m ku-band upgradeable antenna
Hide thumbs Also See for AN6-098P:
Table of Contents

Advertisement

Final steps

Remove the OPI

Check for safety labels and

Subsequent steps

Complete the following steps before leaving the installation site.
Remove the OPI so you can re-use it for subsequent installations:
1. Disconnect the OPI and block, if used.
2. Reconnect the receive cable to the radio.
Make sure the required safety labels and/or signs are present:
signs
• Make sure a Radiation Hazard Caution label is present,
legible, and visible on the feed arm and on the back of the
antenna reflector.
• If the antenna is enclosed by a fence, make sure a Radiation
Hazard Caution sign is present, legible, and visible on the
entrance gate.
• If the antenna is installed on a roof with a permanently
mounted access ladder, make sure a Radiation Hazard
Caution sign is present, legible, and visible on or near the
ladder.
The antenna is now installed and pointed, ready for operation.
To commission the IDU (remote terminal), refer to the IDU
installation manual.
Chapter 7 • Pointing the antenna
1037312-0001 Revision A
69