Introduction The door station is designed with high resolution color CCD camera, it pro- vides wide angle of 105 for DT 2-wire intercom system. The high white LED for night view makes the door station working efficiently at night. The front panel is made of plexiglass or stainless steel with rainy cover for better protection against water.
Lock Control Jumper: To select the lock type. Door Station Code DIP: Total 4 door stations can be supported. T/R+,T/R-: USB-RS485 communication terminal. Main Connect Port: To connect the bus line and the electronic locks. BUS(Blue&Green): Connect to the bus line, non-polarity. PL(White): External lock power input, connect to the power positive(power +).
The location of the unit should keep away from snow,rain,and intensity light. Installation Steps: Installation height for door station usually is 145~160cm. 1. Use screws to fix the back panel and rainy cover(if mounting with rainy cover) to the wall after connect the cable correctly. 2.
Multi Door Stations Connection 4# Camera 3# Camera 2# Camera 1# Camera ID=11 ID=01 ID=10 ID=00 monitors Bus PL S1+ S2+ S- Bus PL S1+ S2+ S- Bus PL S1+ S2+ S- Bus PL S1+ S2+ S- 85~260VAC DIP=on,off,off A B C D DBC-4S Impedance switch...
Electric Lock Connection Door Lock Controlled with Internal Power Note: 1. Electronic lock of Power-on-to-unlock type should be used. 2. The door lock is limited to 12V, and holding current must be less than 250mA. 3. The door lock control is not timed from Exit Button(EB). 4.
connect one lock connect two locks Take off the Jumper Take off the Jumper POWER POWER SUPPLY SUPPLY LOCK LOCK LOCK 5.2.3 Unlock parameter setting(set on monitor) H/W : a1.3 S/W: V17.11.418.00 Manual Monitor Intercom Multimedia Local addr: Monitor Unlock timing: Video standard: UI-CODE: Close...
DIP Switches Setting The DIP switch is designed to set the code ON(1) OFF(0) for door station and monitor, there are two states for each DIP switch, please refer to the sketch map. Door station DIP setting Total 2 bits can be configured, bit-1 and bit-2 are used to assign ID code for door sta- tion.The switches can be modified either before or after installation.
Cables Requirements The maximum distance of the wiring is limited in the DT system. Using dif- ferent cables may also affect the maximum distance which the system can reach. The farest monitor monitor with two or four monitors monitor monitor DBC-4S When Monitor quantity <...
Page 12
Specification Power Supply : DC 24V (supplied by PC6); Power Consumption: Standby 60mA; Working status 200mA; Camera: 1/4 ACS 4T image sensor with DSP processor Lock Power supply: 12Vdc, 300mA(Internal Power); Working temperature: -10ºC ~ +45ºC Dimension: 188(H)×110(W)×34(D)mm Precautions • Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent.