1.Parts and Functions Microphone LCD Screen Mounting Hook RING Connection Port Close Button Mute Button/Indicator Menu Button Return Button Up Button Down Button Talk/Mon Button Unlock Button Terminal Description SW+,SW-: Door bell call button connection port. Ring,GND: Extra buzzer connection port.
1. Use the screws to fix the Mounting Bracket on the mounting box.(fitting accesories includes a Bracket (Two pieces of 4X25 screws are needed for fastening the Mounting Bracket), Special 2 wire connectors to connect with Monitor) 2. Wire the system correctly(see the later connection chapter) then hang the Monitor on the Mounting Bracket firmly.
5.Intercom Function When the monitor is in standby mode, press Menu Button to enter main menu page. Use Button to move upward / downward to select Intercom Call item, press Menu Button to enter the select intercom page, you have 3 items to select. : User in one apartment can call other apartments in the system.
6.Divert Call Function When the monitor is in standby mode, press Menu Button to enter main menu page. Button to move upward / downward to select Divert Call item, press Menu Button to enter the call divert options page, you have 4 items to select. Main Menu Call Divert Options Monitor By Select...
8.Light Function When the monitor is in standby mode, press Menu Button to enter main menu page. Use Button to move upward / downward to select Light item, press Menu Button to enter the light Option page, you have 3 items to select. Main Menu Light Option Light...
10.Restore to Default When the monitor is in standby mode, press Menu Button to enter main menu page. Use Button to move upward / downward to select Restore item, press Menu Button to enter the restore page, and then press Menu Button to confirm.
Page 8
11.4 How to set the slave monitor address Maximum 4 monitors can be connected in one apartment,one master monitor together with 3 slave monitors, so you should set the address correctly.(note:must have one monitor to be set as master monitor) The code of 8000 is used to set the master monitor.
Page 9
11.7 User Code Setup In the DT system,every apartment must have a unique identification called User Code. The DIP swiches are used to configure the User Code for each Monitor. • Bit-1 to Bit-5 are used to User Code setting. The value is from 1 to 32, which have 32 different codes for 32 apartments.
12. Basic Connection door station BUS(IM) BUS(DS) Doorbell Button RING Switch 13.Screen and Volume Adjustment During monitoring or talking, press Menu Button, the will be displayed. ADJUST MENU Menu Button to select the adjustment item; use Button to decrease / increase the value, press Button to quit the adjust page...
Page 12
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved. DT-ENG-43/D4-V1...