Extron electronics PowerCage 1600 User Manual page 16

Modular power enclosure for fiber optic and twisted pair extenders
Hide thumbs Also See for PowerCage 1600:
Table of Contents

Advertisement

c
Fan status LEDs — These LEDs indicate whether the fans that cool the enclosure are
operating.
FAN
FAN
1
2
Power LED — Lights when the corresponding fan receives power.
Alarm LED — Lights when the corresponding fan malfunctions.
d
Communication selection (Comm Select) button — Press this button to select
the desired board to connect to the Config port (
serial connection changes from one active, installed board to the next. The Comm LED
a
(see
) for the selected board lights.
NOTES:
When unit power is cycled (removed then restored), the serial connection
returns to the board in the lowest-numbered slot.
The Comm LED lights for each installed, powered board as its slot is
selected, regardless of the type of board. However, RS-232 communication
works only with FOX boards; commands and queries cannot be sent to or
passed through the MTP boards.
e
Configuration and communication (Config) port — For RS-232 serial
communication with any installed board, connect a Windows
control system to this 2.5 mm mini stereo-style (tip-ring-sleeve) jack. Use the Extron
9-pin D to 2.5 mm st ereo mini TRS RS-232 cable (part number 70-335-01, shown in the
following figure) or make your own cable.
1
6
9
5
9-pin D
Connection
Pin 2
Computer's Rx line
Pin 3
Computer's Tx line
Pin 5
Computer's signal ground
Figure 7.
9-pin D to 2.5 mm Stereo Mini TRS RS-232 Cable
RS-232 protocol varies depending on the board being communicated with (see the
specifications
section), but all boards accept this basic set of protocol:
• 9600 baud
• 1 stop bit
• 8 data bits
NOTE:
This port allows serial communication to the boards only, not to the
enclosure, itself. The power supply and fan status LEDs provide feedback
about the condition of the enclosure.
f
Temperature status (Temp) LED — This LED lights when the unit as a whole
is operating at a dangerously high temperature (approximately 167 °F [75°C]) and
equipment damage is imminent. If the Temp LED lights, power down the unit, ensure
adequate ventilation, and allow the PowerCage system to cool before restoring power.
e
). With each button press, the
6 feet
(1.8 m)
Part 70-335-01
TRS Plug
Tip
Ring
Sleeve
• no parity
• no flow control
PowerCage 1600 Enclosure • Operation
®
-based PC or an RS-232
Tip
Ring
Sleeve (Gnd)
10

Advertisement

Table of Contents
loading