Page: 36
Service Manual - OKIPAGE10i
Chapter 3 Parts Replacement
(1) Remove the upper cover assy (see 3.3.1).
(2) Remove the operator panel assy (see 3.3.4).
(3) Remove the face up stacker assy (see 3.3.8).
(4) Remove the reset lever R (1).
(5) Detach the reset spring (2) from the lower base unit (3), turn the reset lever L (4) in the direction of
arrow A until it stops, and remove it in the direction of arrow B .
(6) Unlock two latches of the lower base unit (3), then remove the stacker cover assy (5).
Note: When reinstalling the reset lever L (4), fit it onto the guide of the lower base unit (3), turn it in the
direction of arrow C while pressing down the shaft of back up roller, and engage the reset lever L (4).
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)