Nibe AP-AW10 Operating Manual page 20

Air/water compact heat pumps
Table of Contents

Advertisement

Insert the power line and the sensor wires into the
unit through the rubber sockets on the back of the
unit...
1 Rubber sockets
for positioning of the rubber sockets for
inserting the wires, see "dimensional drawing"
for the respective model.
The wires inside the unit are guided in a closed wire
duct to the switch cabinet...
1 Wire duct in unit
2 cable glands switch cabinet
3 connections for power
and control wires
4 connections for regulator board
Install electric connections according to the
terminal diagram that applies to your model...
Terminal diagram for respective model.
20
NIBE
AP-AW10
TM
We reserve the right to make technical changes
attentIon
Ensure clockwise rotary field of the load power
supply (compressor).
An incorrect rotary field of the compressor
during operation can cause serious, irreparable
damage to the compressor.
attentIon
make sure to equip the power supply of the heat
pump with a 3-pole automatic cut-out with at
least 3mm contact gap.
Note the level of the release current.
1
overview "Technical data / scope of delivery",
"Electric" section.
E
D
CautIon.
The sensor cable for heat quantity recording
may not be shortened!
C
notICe.
The control element of the heat and heat pump
regulator can be a connection with a computer
or network using an network cable designed for
such pruposes, thus allowing the heating and
B
heat pump regulator to be controlled remotely.
If such a connection is desired, install a screened
network cable (category 6, with RJ-45 plug)
Blattformat: A4 hoch
through the unit when installing the connections
Allgemein-
and run it through the front facade of the unit,
toleranz
DIN ISO 2768 -c
parallel to the already-present heating and heat
Erstellt
pump regulator control cable.
Gepr.
Norm.
Alpha-InnoTec GmbH
Industriestraße 3
D - 95359 Kasendorf
close electrical switch cabinet of unit.
-
9.2.2009
HS
www.alpha-innotec.de
Zust.
Änderungstext
Datum
Von
83050406cUK – Translation of the operating manual
2
3
1:2
Maßstab
Ober ächen
Werksto
-
---
Datum
Name
Benennung
Durch usssensor VFS5-100
9.2.2009
Stenglein
ArtikelNr.
603772
Ers. f.
4
Schutzvermerk nach DIN 34 beachten
Det. Maßstab
Gewicht
Blatt
1
von
1
Ers. d.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap-aw10-6cAp-aw10-8cAp-aw10-10cAp-aw10-12c