Install The Vent Pipe; Install The Log Set - Vermont Castings SDDVTCB Homeowner's Installation And Operating Manual

Direct vent/natural vent gas heater sddvt series/sddvtc series
Table of Contents

Advertisement

Stardance® Direct Vent/Natural Vent Gas Heater
For U.S. installations: The venting system must conform
with local codes and/or the current National Fuel Gas
Code, ANSI Z22.1.
For Canadian installations: The venting system must
conform to the current CSA B149.1 installation code.

Install the Vent Pipe

Apply a bead of sealant around bottom end of inner starter
pipe (found in bag with logset) and attach to stove. Apply
a bead of sealant around top of inner starter pipe and in-
stall the Z31B00 FSDHAG Draft Hood according to Draft
Hood instructions. (Fig. 45)
Attach the first section of venting to the draft hood. De-
pending on the length of the individual venting sections
and the lengths of the decorative pipe (if installed), you
may need to slip the decorative pipe over the venting sec-
tions before attaching upper sections to lower ones. The
sections of decorative pipe should be oriented with their
seams (if any) toward the wall; sections usually do not
need to be fastened at each joint, other than slip sections.
If the layout includes a slip section, this should be the last
section of pipe visible in the room, at the ceiling. Complete
the venting according to the vent maker's instructions.
CAUTION: Before installation, inspect ember bed burner
for damage. Do not use ember bed if damaged or cracked.
NOTE: Small, shallow surface cracks are acceptable.
1. Remove the logs from their packaging and inspect
each piece for damage. DO NOT INSTALL DAM-
AGED LOGS.
2. Install the rear log by mating
the notch on the bottom of
the log with the raised notch
on the back left side of the
ember bed. (Fig. 47) Ensure
the cutout in the right side of
the log is sitting around the
pilot assembly and pilot is not
obstructed. (Fig. 46)
26
Draft Hood
Adapter
Fig. 45 Decorative 7" pipe may be fitted around the B-vent
pipe.

Install the Log Set

Figure 46
Decorative
7" Pipe
4" B-vent
Pipe
ST358
Decorative
pipe around b-vent
4/26/00 djt
Rear Log
Vermont Castings
Group Direct Vent
System may be
used after Draft
Hood up to the
ST358
LG493
30004968

Hide quick links:

Advertisement

Table of Contents
loading