Refer to pages 8 and 9 of this manual for the minimum
and maximum venting requirements of your stove and
for approved horizontal vent termination locations prior
to installation. Failure to do so may cause fire hazard.
!
Any horizontal run must have a 1/4" rise for every one (1)
foot of run towards the vent termination. Never allow the
vent pipe to run down. This could cause high temperatures
and may present a fire hazard.
!
Termination cap must be positioned so the embossed
arrow is pointed up.
General Information
The Stardance is approved for installation only with the
vent components listed in the "Approved Vent System
Components" section in this manual. Follow the vent
component instructions exactly.
For U.S. installations: The venting system must conform with
local codes and/or the current National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
For Canadian installations: The venting system must conform
to the current CSA B149.1 installation code.
Install the Vent Adapter Pipe (HHT SLP Vent
Components)
1. Attach Inner Starter Pipe, (found in the Parts Bag), to the
next section of inner pipe.
2. Run a bead of sealant about 1/2" from the upper end of
the Inner starter pipe and join the two sections together.
3. Drill three pilot holes into the Inner Starter and secure
the assembly with three sheet metal screws. (Figure 20)
4. Dry fit the Inner Pipe assembly to the stove for the
purpose of determining the center line of the pipe on the
wall.
5. Side Wall Terminations: Dry fit the outer elbow with the
vertical outer vent and confirm the centerline alignment
with the wall thimble opening.
17
WARNING
WARNING
WARNING
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
Figure 20 - Connect the inner starter with the next section of
inner vent pipe.
1. Attach the Inner Vent Assembly to the stove.
2. Place a 3/8" bead of millpack caulk around the inside of
the cast starter collar. Insert the 6-5/8" outer adapter into
the cast outer starting collar and press down firmly.
3. Install the CCSLP Outer Adapter Pipe.
4. Place a 3/8" bead of millpack caulk around the 4"
crimped end of the starter collar on the stove. Attach the
SLP pipe to the adapter, and secure by aligning adapter
and pipe seams, pressing down firmly until pipe stops,
and twisting to lock into place. (Figure 21)
Figure 21 - Attach inner assembly to flue collar.
ST647
attach inner assy
ST211
attach inner pipe
to next section