2.4. Accessories
The following installation accessories are supplied. Use
them as required.
Name and Shape
Q'ty
Operating Manual
Installation Manual
(This manual)
Wall hook bracket
Remote controller
Battery
The following items are necessary to install this air condi-
tioner. (The items are not included with the air conditioner
and must be purchased separately.)
Name
Connection pipe assembly
Connection cable (4-conductor)
Wall pipe
Decorative tape
Vinyl tape
Wall cap
Saddle
Drain hose
Tapping screws
Sealant
En-4
9332279030-04_IM.indb 4
9332279030-04_IM.indb 4
Name and Shape
Q'ty
Remote controller
holder
1
1
Cloth tape
1
1
Tapping screw
(big)
1
8
Tapping screw
(small)
1
2
Air cleaning filter
2
2
Q'ty
1
1
1
1
1
1
1 set
1
1 set
1
2.5. Optional parts
Refer to each installation manual for the method of installing
optional parts.
Parts name
Model No.
Wired Remote
UTY-
Controller *
RNNUM
Wireless Remote
UTY-
Controller
LNHUM
Simple Remote
UTY-
Controller *
RSNUM
UTY-
External connect kit *
XWZX
UTY-
Communication kit
XCBXZ1
* Optional communication kit is necessary for the installation.
3. GENERAL
This INSTALLATION MANUAL briefly outlines where and how to
install the air conditioning system. Please read over the entire set
of instructions for the indoor and outdoor units and make sure all
accessory parts listed are with the system before beginning.
3.1. Type of copper pipe and insulation
material
CAUTION
Refer to the installation manual for the outdoor unit for
description of allowable pipe length and height difference.
Diameter
Liquid pipe
6.35 mm (1/4 in.)
CAUTION
Install heat insulation around both the gas and liquid
pipes. Failure to do so may cause water leaks.
Use heat insulation with heat resistance above 248 °F.
Reverse cycle model only)
In addition, if the humidity level at the installation lo-
cation of the refrigerant piping is expected to exceed
70%, install heat insulation around the refrigerant pip-
ing. If the xpected humidity level is 70-80%, use heat
insulation that is 15 mm (19/32 in.) or thicker and if the
expected humidity exceeds 80%, use heat insulation
that is 20 mm (25/32 in.) or thicker.
If heat insulation is used that is not as thick as speci-¿ ed,
condensation may form on the surface of the insulation.
In addition, use heat insulation with heat conductivity
of 0.045 W/(m•K) or less (at 68 °F).
3.2. Additional materials required for
installation
A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire (See your
local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping
Application
For air conditioner
operation
For air conditioner
operation
For air conditioner
operation
For control input/output
port
For the installation of
optional parts
Gas pipe
9.52 mm (3/8 in.)
9/8/2010 9:56:05 AM
9/8/2010 9:56:05 AM