Cooling Mode: Settings for either Low, Mid or High Cooling. This affects fan speed with reference to
the temperature measured internally. While there is no universal preferred setting, we recommend that
unless noise levels are a concern, you leave the setting on Mid or High for coolest operation and best
protective results.
Terminations:
Shutdown:
Reboot:
Reboot maintenance
System Info (Set Up):
In this sub menu you will find details on the Horus internals; current consumption, voltage, temperature,
fan speed, serial number and the firmware version currently installed.
Low: Fan starts above 45°C
Mid: Fan starts above 35° C
High: Fan always on at lowest speed (less noise), speed starts rising above 25
° C
75 for WCK: Sets 75 termination for the Wordclock Input. Enabling this will
disable the Wordclock output.
75 for Video: Sets 75 termination for the Video reference Input. Unless the
Video Reference signal provided to the Horus is daisy-chained to other
equipment, you should always terminate your Video signal for most reliable
operation.
Initiates a proper shutdown of the Horus unit, including a save of the current
configuration. Do not attempt to shutdown the Horus unit in other ways (such
as using the power switch on the back of the device).
Power cycles the Horus unit (shutdown>Boot up)
Power cycles the Horus unit (shutdown>Boot up) and restarts in Maintenance
mode (required mode for Firmware upgrade)