Line Output Level calibration
The DA8 and DA8P modules feature both hardware level settings in the form of 4 DIP switches per
output channel and a software fine adjustment to align the Analog Output levels to whatever
local/organization operational levels are mandated.
The Hardware settings are usually to be set only once, at product installation, and only if the desired
Operating Line Level differs from the default ex-factory settings of +18 dBu for 0 dBFS.
Procedure for Hardware alignment:
1. Shut down your Horus and make sure that the Horus back panel Power is also switched OFF.
2. Unscrew all DA8 modules that need adjustment.
3. Pull gently out (5-7 cm is enough) to access the DIP Switches. There is one block of 4 dip switches
per channel. Channel 1 is labeled S1, channel 8 is labeled S8.
4. Set the DIP Switches as per the table legend printed on the DA8 module card
Output Level (dBu)
+24
+18
1
2
ON
Switch
S1 to S8
3
ON
4
www.merging.com/horus
+15
+12
ON
ON
ON
ON
ON
ON
Horus User Manual