Power Supply - Elation TVL3000-II WW User Instructions

Elation dmx intelligent led fixture user instructions
Table of Contents

Advertisement

TVL3000-II WW/CW/DW

Power Supply:

The Elation Professionals
TVL3000-II CW, and TVL3000-II DW contain an automatic voltage
switch, which will auto sense the voltage when it is plugged into the
power source. With this switch there is no need to worry about the
correct power voltage, this unit can be plugged in anywhere. Also be
sure to only use the included I.E.C. power cable supplied with the unit.
DMX-512:
DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA "IN" and DATA "OUT" XLR terminals located on all DMX
fixtures (most controllers only have a DATA "OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models of
different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave
Operation): The TVL3000WW-II & TVL3000CW-II have 1 DMX chan-
nel, while the TVL3000-II DW has 2 DMX Channel Modes. The DMX
address is set electronically using the controls on
the rear of the unit. Your unit and your DMX con-
troller require a approved DMX-512 110 Ohm Data
cable for data input and data output. We recom-
mend Accu-Cable DMX cables. If you are making
your own cables, be sure to use standard 110-120
Ohm shielded cable (This cable may be purchased
at almost all professional sound and lighting
stores). Your cables should be made with a male
and female XLR connector on either end of the cable. Also remember
©Elation Professionals® - www.elationlighting.com - TVL3000-II WW/CW/DW User Manual Page 5
Set Up
TVL3000-II WW,
®
REMOTE
INPUT
OUTPUT
SOUND
CONTROL
INPUT
POWER
DMX512
DMX+,DMX-,COMMON
1
DMX512 OUT
3
3-PIN XLR
2
Figure 1
SOUND
TVL3000-II WW/CW/DW
that DMX cable must be daisy chained and cannot be split.
Notice:
Be sure to follow figures two and three when making your
own cables. Do not use the ground post on the XLR connector. Do
not connect the cable's shield conductor to the ground lug or allow
the shield conductor to come in contact with the XLR's outer casing.
Grounding the shield could cause a short circuit and erratic behavior.
DMX512 OUT
3-PIN XLR
XLR Male Socket
1 Ground
2 Cold
3 Hot
REMOTE
INPUT
SOUND
CONTROL
Figure 3
INPUT
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
COMMON
DMX +
1
DMX512 IN
3
3-PIN XLR
DMX -
2
©Elation Professionals® - www.elationlighting.com - TVL3000-II WW/CW/DW User Manual Page 6
REMOTE
INPUT
OUTPUT
CONTROL
SOUND
INPUT
POWER
DMX512
DMX+,DMX-,COMMON
COMMON
DMX +
1
1
3
3
DMX -
2
2
XLR Female Socket
2 Cold
1 Ground
3 Hot
OUTPUT
SOUND
When longer runs of cable are
POWER
Termination reduces signal errors and
avoids signal transmission problems
1
and interference. It is always advisable
3
to connect a DMX terminal, (Resistance
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
Set Up
POWER
Termination red
avoids signal t
1
DMX512 IN
and interference
3
3-PIN XLR
to connect a DM
2
120 Ohm 1/4 W)
Figure 2
and PIN 3 (DMX
XLR Pin Configuration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
POWER
Figure 4
SOUND