Connecting Chemical Containers Or Dispensers - Meiko DV 120.2 Owner's Installation, Operation And Maintenance Manual

Door-type variotronic high temperature sanitizing utensil washer (usa version)
Table of Contents

Advertisement

S
3 - I
ECTION
NSTALLATION
3.10 Connecting Chemical Containers or
Dispensers (if so equipped)
This section applies to units with either
internal or external chemical dispensing
pumps.
1. Check that the rinse additive and
detergent are compatible with the unit. In
particular, a commercial (not a domestic)
detergent MUST be used.
2 Check that the containers/dispensers are
correctly installed according to the
manufacturer's instructions.
3. If the utensil washer is equipped with
factory internal chemical dispensing
pumps, two strainer assemblies for the
chemical containers are also included.
See Figure 3-12. These strainers should
be assembled onto the lids for the
detergent and rinse additive containers.
Page 10
4. For liquid detergent systems, locate the
5. Locate the BLUE liquid rinse additive tube
6. If using the strainers shown in Figure
Figure 3-12: Strainer assembly
Lid for detergent
or rinse additive
container
Strainer
tube
CLEAR liquid detergent tube. Connect the
tubing to the detergent container.
For solid detergent systems, connect the
detergent supply line according to the
manufacturer's instructions.
at the lower rear of the unit. Connect the
tubing to the rinse additive container.
3-12, be sure to use the supplied wire
clamps to fasten the chemical supply
tubes securely. MEIKO STRONGLY
RECOMMENDS the use of a sealing
compound on these connections to
prevent leakage.
Wire
clamp

Hide quick links: