3.10 Connecting Chemical Containers or
Dispensers (if so equipped)
This section applies to units with either
internal or external chemical dispensing
pumps.
1. Check that the rinse additive and
detergent are compatible with the unit. In
particular, a commercial (not a domestic)
detergent MUST be used.
2 Check that the containers/dispensers are
correctly installed according to the
manufacturer's instructions.
3. If the dishwasher is equipped with factory
internal chemical dispensing pumps, two
strainer assemblies for the chemical
containers are also included. See Figure
3-11. These strainers should be
assembled onto the lids for the detergent
and rinse additive containers.
Page 10
4. For liquid detergent systems, locate the
5. Locate the BLUE liquid rinse additive tube
6. If using the strainers shown in Figure
Figure 3-11: Strainer assembly
clamp
Lid for detergent
or rinse additive
container
Strainer
tube
CLEAR liquid detergent tube. Connect the
tubing to the detergent container.
For solid detergent systems, connect the
detergent supply line according to the
manufacturer's instructions.
at the lower rear of the unit. Connect the
tubing to the rinse additive container.
3-11, be sure to use the supplied wire
clamps to fasten the chemical supply
tubes securely. Meiko STRONGLY
RECOMMENDS the use of a sealing
compound on these connections to
prevent leakage.