Performing Preventative Measures On Disk Drives And Vds - Intel RAID High Availability Storage User Manual

Table of Contents

Advertisement

®
5. Right-click the Intel
RAID High Availability Storage controller and select Update Driver Software
to start the Driver Update wizard.
6. Follow the instructions in the wizard.

Performing Preventative Measures on Disk Drives and VDs

The following drive and VD-level operations help to proactively detect disk drive and VD errors that
could potentially cause the failure of a controller node. For more information about these operations, refer
to the Intel(R) RAID Software User's Guide.
Patrol Read – A patrol read periodically verifies all sectors of disk drives that are connected to a
controller, including the system reserved area in the RAID configured drives. You can run a patrol
read for all RAID levels and for all hot spare drives. A patrol read is initiated only when the
controller is idle for a defined time period and has no other background activities.
Consistency Check – You should periodically run a consistency check on fault-tolerant virtual drives
(RAID 1, RAID 5, RAID 6, RAID 10, RAID 50, and RAID 60 configurations; RAID 0 does not
provide data redundancy). A consistency check scans the virtual drives to determine whether the data
has become corrupted and needs to be restored.
For example, in a VD with parity, a consistency check computes the data on one drive and compares
the results to the contents of the parity drive. You must run a consistency check if you suspect that
the data on the VD might be corrupted.
NOTE: Be sure to back up the data before running a consistency check if you think the data might be
corrupted.
52
Figure 42 Updating the Driver Software
®
Intel
High Availability Storage User Guide

Advertisement

Table of Contents
loading

Table of Contents