Intel RAID High Availability Storage User Manual page 60

Table of Contents

Advertisement

Disk bus type does not
support clustering. Disk
partition style is MBR. Disk
partition type is BASIC.
No disks were found on
which to perform cluster
validation tests.
When booting a controller node,
the controller reports that it is
entering Safe Mode. After
entering Safe Mode, the
controller does not report the
presence of any drives or
devices.
The Intel management
applications do not present or
report the HA options and
properties.
Drives are not reported in a
consistent manner.
The management application
does not report a VD or disk
group, but the VD or disk group
is visible to the OS.
60
operating system does not
natively support internal RAID
controllers for clustering.
controller parameter is detected.
The peer controller is prevented
from entering the HA domain.
compatible with the controller in
the HA domain. Entering Safe
Mode protects the VDs by
blocking access to the controller
to allow for correction of the
incompatibility.
The version of the management
applications might not be HA-
compatible.
Improper connections might
impact the order in which the
drives are discovered.
The shared VD is managed by
the peer controller.
Confirming SAS Connections.
Confirm that the version (or
the current settings) of the
operating system supports
internal RAID controllers.
have settings that do not match
the controller. To correct this
situation, update the firmware for
the peer controller and the other
controller, or both, to ensure that
they are at the same firmware
version.
does not exactly match the
controller. To correct this
situation, replace the peer
controller with a unit that
matches the controller hardware.
Obtain an HA-compatible
version of the management
application from the Intel web
site, or contact an Intel support
representative.
Make sure you are following the
cabling configuration guidelines
listed in Section - Cabling
Configurations.
The VD or drive group can be
seen and managed on the other
controller node. Log in or open a
terminal on the other controller
node.
®
Intel
High Availability Storage User Guide
ntroller hardware

Advertisement

Table of Contents
loading

Table of Contents