Learances To Ombustibles; C Ombustibles; C Learances To - HearthStone 8761 Owner's Manual

Gas-fired direct vent heater
Hide thumbs Also See for 8761:
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc.
Specification
Input rating (Btu/hr) 0-2000 ft
Input rating (Btu/hr) 2000-4500 ft
Orifice size DMS 0-2000 ft
Orifice size DMS 2000-4500 ft
Man. press.-LO setting (in.w.c./kPa)
Man. press.-HI setting (in.w.c./kPa)
Inlet press.-LO setting(in.w.c./kPa)
Inlet press.-HI setting(in.w.c./kPa)
Minimum input rating rating (Btu/hr)
Maximum output (Btu/hr) 0-2000 ft
C
C
LEARANCES TO
Always maintain clearances around the air openings in the stove. This allows for adequate ventilation. (As
shown in Figures 2 & 3)
2" MIN.
1" MIN.
4" MIN.
Figure 3 - Rear and side wall clearances
The corner clearance for the Santa Fe is 2", measured from the edge of the top castings to the adjacent
wall.
H
R
/ F
EARTH
EQUIREMENT
You can place the Santa Fe on a non-combustible
surface, or wood floor. For placement on carpeting,
vinyl tile, or other combustible materials, the
appliance must be installed on a panel consisting of
wood or any noncombustible material (metal, glass,
Figure 2 – Ratings and Settings
OMBUSTIBLES
P
LOOR
ROTECTION
SANTA FE 8761 Gas-Fired Direct Vent Heater
NG
35,000
35,000
32
32
1.2/0.3
3.5/0.87
5.0/1.24
7.0/1.74
21,500
25,600
Figure 4 - Top clearances (not to scale)
stone, etc.) extending the full width and depth of the
appliance. Installations must meet all codes.
LP
35,000
33,300
49
50
3.3/0.8
10.0/2.48
11.0/2.88
13.0/3.22
20,400
25,600
17" max.
2" MIN.
14" MIN.
Page 8 of 31