VideoJet X20 SN
1.
2.
3.
CAUTION!
!
If you change the IP address, subnet mask or gateway address, the VideoJet X20 SN is only
available under the new addresses after the reboot.
5.28.1
IP address
Enter the desired IP address for the VideoJet X20 SN. The IP address must be valid for the
network.
5.28.2
Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
5.28.3
Gateway address
If you want the unit to establish a connection to a remote location in a different subnet, enter
the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
5.28.4
DNS server address
The VideoJet X20 SN is easier to access if the unit is listed on a DNS server. If you wish, for
example, to establish an Internet connection to the VideoJet X20 SN, it is sufficient to enter
the name given to the unit on the DNS server as a URL in the browser. Enter the DNS server's
IP address. Servers are supported for secure and dynamic DNS.
5.28.5
Video transmission
If the unit is operated behind a firewall, TCP (HTTP Port) should be selected as the transfer
protocol. For use in a local network, select UDP.
CAUTION!
!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not
support multicast connections.
The MTU value in UDP mode is 1,514 bytes.
5.28.6
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If
you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In
this case, select Off.
Bosch Security Systems
Make the desired changes.
Click the Set button.
Click a Reboot link to trigger a reboot. VideoJet X20 SN is rebooted and the changed
settings are activated.
Installation and Operating Manual
Configuration Using a Web Browser | en
77
V3.5 | 2007.12