5.26.3
Relay follows
If required, select a specific event that will trigger the relay. The following events are possible
triggers:
NOTICE!
i
The numbers in the lists of selectable events relate to the corresponding connections on the
unit, Video alarm 1, for example to the Video In 1 connection.
5.26.4
Relay name
You can assign a name for the relay here. The name is shown on the button next to Trigger
relay. The Livepage can also be configured to display the name under the relay icon.
5.26.5
Trigger relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for
example).
Bosch Security Systems
Off
Relay is not triggered by events
Connection
Trigger whenever a connection is made
Video alarm
Trigger by interruption of the video signal at the corresponding input
Motion alarm
Trigger by motion alarm at the corresponding input, as configured on the VCA page (see
Section 5.23 VCA, page 64)
Local input
Trigger by the corresponding external alarm input
Remote input
Trigger by remote station's corresponding switching contact (only if a connection exists)