Install Aqua-Sensor

1.
Measure the sensor cable length as shown in dimension Y. See
Sensor cord is set at the factory for a 9" tank).
Tank Model
9" Quadra-Hull™ Tank
10" Quadra-Hull Tank
12" Quadra-Hull Tank
14" Quadra-Hull Tank
2.
Loosen the small Aqua-Sensor Plug; a needle-nose pliers works
best. See Figure 3.
3.
Moisten the cable sheath and slide the cable grip up or down to
the proper cable length.
4.
Tighten the small Aqua-Sensor plug so that the fitting cannot slide
along the cable.
NOTE
There must be no kinks or bends in the cable.
5.
Insert the probe and cable through the Aqua-Sensor port.
6.
Tighten the Aqua-Sensor plug into the Aqua-Sensor port.
NOTE
The media tank must be backwashed so that the Aqua-Sensor probe can
fall into the proper position. See
Procedure" on page
Dimension Y
40"
44"
42"
52"
Table 1. HE cable lengths.
"Recommended Aqua-Sensor® Start-Up
39.