The controller display, as well as the Remote Display (if connected), may display the following errors.
PROBLEM FOUND
APR-01-13 10:01A
REPLACE FILTER
MEDIA
-->CLEAR ERRORS
-->GO TO MENU
Error
Reason for Error
Aqua-Sensor did not detect brine
Aqua Salt Err
during the regeneration cycle.
An Aqua-Sensor was "Installed" but
main board detects the Aqua-Sensor
Aqua Sens Probe
is not connected. The board might not
be detecting the 2.5V power supply
Auxiliary Input is configured as alarm
Auxiliary Alarm
contacts and was closed for the pre-
scribed amount of time.
The brine draw rate of water to the
Brine Blocked
brine tank was longer than normal.
Too much water in brine tank.
Plugged drain line flow control (Unit
will not draw brine).
Plugged eductor system (Unit will not
draw brine).
Brine Overfill
Slow leak to brine line.
Faulty eductor piston.
Power outage while control was in
refill position.
This message is displayed if an error
Call Culligan at
has been detected that requires ser-
vicing and no modem installed in the
xxx-xxx-xxxx
system.
Aqua-Sensor did not detect brine
Check Brine Tank
during the regeneration cycle.
SBT sensor indicated improper sig-
Check SBT Sensor
nals at the beginning of the refill
cycle.
1.
When the controller identifies an error, it is programmed to attempt
to correct the error without user input. If the problem persists, the
HOME SCREEN displays PROBLEM FOUND. Press
the first error present.
2.
Press
to display any additional errors present.
3.
Press
and
to view action: CLEAR ERRORS, GO TO MENU,
or EXIT. If you select CLEAR ERRORS, the controller checks the
error status and attempts to clear the error. If the error still exists, the
home screen displays PROBLEM FOUND. If the error no longer ex-
ists the screen displays SYSTEM OK.
4.
Press
to select CLEAR ERRORS, GO TO MENU, or EXIT.
Comment/ Clearing Error Message
Check brine tank and add salt if necessary. Check Z
ratio of the Aqua-Sensor at Main Menu/Advanced/
Diagnostics/Check Sensors
Check connection of Aqua-Sensor to the main board.
Check the device that is connected to the Auxiliary
Input.
Check brine line for blockages or air leaks. Check
eductor and eductor screen for blockages
Check eductor; check for brine draw.
Clean drain line flow control.
Clean eductor screen and nozzle
Replace eductor piston
Call the number shown. If possible, place this call using
a phone that will allow you to see and enter changes to
the main controller if required by the service technician
during the call
Check brine tank and add salt if necessary. Check Z
ratio of the Aqua-Sensor at Main Menu/ Advanced /
Diagnostics/ Check Sensors
The SBT sensor may have an obstruction causing the
optical detection paths to all be blocked at once; possi-
ble electrical open/short in SBT pcb or wire harness.