Position the Mineral Tank(s)
Determine the location for the mineral tanks(s) prior to loading, because they will be difficult to move after
the underbedding and gravel are loaded.
Heater
Load the Tank (12" and 14" Tanks)
1.
Position the tank so that the Culligan
2.
Remove the inlet strainer.
3.
Install the outlet manifold into the tank (Figure 2).
4.
Cover the tops of the manifolds with a clean rag.
5.
Using a large-mouth funnel, load the Culligan underbedding
through the top of the tank.
CAUTION! DO NOT allow the outlet manifold
6.
Load the tank with the Cullex
required.
7.
Remove the funnel.
8.
Install the inlet strainer making sure to thread the strainer until it
bottoms out on the tank thread. Failure to install the strainer cor-
rectly can cause the control to leak.
Treated Water Out
Drain Line
Figure 1.
HE system placement.
logo is in the front.
®
to move when loading the media.
The manifold must remain vertical
to ensure a good seal at the gasket.
Rap the tank near the bottom with a
rubber mallet to level the sand.
ion exchange resin. Leveling is not
®
Hard Water In
Air Gap
(2x Pipe Diameter
Brine Tank
or 1 inch, whichever
is larger)
Figure 2.
To
Hose
Bibs
Water
Meter
or
Pump
HE Softener tank.