There are several conditions that will cause the control to trip a regeneration. The screen displays REGEN
Tonite when the control has signaled for a regeneration. Regenerating is displayed while the control is in
regeneration. The following are conditions that will call for regeneration:
1.
When the Soft-Minder® meter has recorded the passage of a predetermined number of gallons.
2.
When the Aqua-Sensor® Probe senses the hardness in the Cullex Media.
3.
At the preset time, when the number of days without a regeneration is equal to the regeneration
interval (timeclock backup) setting.
4.
At the preset time, when Regen Tonite is selected. The screen displays Regen Tonite.
5.
Immediately, when the Regen Now is selected. The screen displays Regenerating.
6.
Immediately, if power to the unit has been off for more than three hours and the time of day has
been restored.
7.
At the preset time based on "Day-of-Week" Regeneration setting.
Follow either procedure to bypass the softener or to initiate a manual regeneration or automatically by-
pass the softener at the control valve or the remote display.
Delayed Regeneration
Screen Display
SOFTENING
JAN-01-13 12:01P
REGEN TONITE
JAN-01-13 12:01P
REGEN OFF
JAN-01-13 12:01P
Immediate Regeneration
Screen Display
SOFTENING
JAN-01-13 12:01P
REGEN NOW
JAN-01-13 12:01P
REGENERATING
JAN-01-13 12:01P
Range
From the HOME screen, press
1.
N/A
three (3)seconds and then release the button.
2.
The screen displays the regeneration status on the first
Regen
line of the display. The system will regenerate at a
Tonite
scheduled time.
3.
To cancel a delayed regeneration, press
Regen
for at least three (3) seconds and then release the but-
Off
ton. The screen displays the new status.
Range
1.
From the HOME screen, press
N/A
ten (10) seconds.
2.
The screen displays the regeneration status on the first
Regen
line of the display. The softener will initiate an immedi-
Now
ate regeneration.
The first line of the screen displays REGENERATING.
N/A
3.
Setting Description
and hold for at least
Setting Description
and hold for at least
and hold

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

10"14"12"

Table of Contents