Culligan 9" Owner's Manual page 50

High efficiency automatic water softener
Table of Contents

Advertisement

01021076
46
Low Battery
Battery needs replacement.
Salt level is low; less than 15 days of
Low Salt Level
salt remaining.
The controller failed to detect proper
position sensor feed back during INI-
Motor Home Err
TIALIZATION (not during a regen or
progressive flow)
Failure to refill brine tank. Refill re-
strictor plugged.
No Refill
Air in brine line cause float to slam
shut.
No Remote
Main board is not receiving a signal
Signal
from the remote.
The controller is seeking a known
Pos Sensor Err/
valve position before/during/after a
regen, or during progressive flow, but
Motor Position
cannot find it (this error does NOT
Error
appear during initialization).
Total gallons through the secondary
filter (i.e. "Big Blue" filter) has ex-
Replace Ext Filt
ceeded the specified capacity of the
Big Blue.
Brine tank has low concentration of
Salt Bridging
brine, but solid salt exists above the
liquid brine level.
Replace with Panasonic Model# CR 2032 3V battery
Contact Culligan dealer for salt delivery or fill brine
tank with salt.
Verify that the proper valve type was selected in First
Time Setup. Check connections of motor and position
sensors at both the motor and the GBE board.
Clean or replace refill restrictor.
Verify all tubing connections are properly assembled.
Remote is off, out of range or on a different channel
from the main board. If interference is suspected, try
moving the remote closer or switching to a different
channel on both the main and remote units
Check connections of motor and position sensors at
both the motor and GBE board.
Replace optional filter cartridge. Reset the external fil-
ter media life at Main Menu/ Accessories/ Ext. Filter
menu
Use a tool to break up any salt bridge inside the brine
tank