10. Cleaning the Hopper
Frequency: Monthly or every 50 bags of fuel
By: Homeowner
After burning approximately 1 ton of fuel you will need to
clean the hopper to prevent sawdust build-up. A combi-
nation of sawdust and pellets on the auger reduces the
amount of fuel supply to the fi repot. This can result in
nuisance shutdowns and mis-starts.
1. The appliance must be in complete shutdown. Allow the
appliance to completely cool down.
2
Empty the hopper of any remaining pellets.
3. Vacuum the hopper and feed tube.
11. Cleaning Exhaust Blower - Requires No Lubrication
Frequency: Yearly or as needed
By: Quality Service Technician/Homeowner
a. Remove left & right cast brick. The exhaust blower
is behind the right cast brick. Vacuum this area
thoroughly. See pages 39 & 40 for removing the cast
bricks. Re-install cast bricks when done.
12. Cleaning Convection Blower - Requires No
Lubrication
Frequency: Yearly or as needed
By: Qualifi ed Service Technician
Task: Contact your local dealer.
13. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
Frequency: Yearly or more frequently depending on
ash build-up
By: Qualifi ed Service Technician/Homeowner
The products of combustion will contain small particles
of fl yash. The fl yash will collect in the exhaust venting
system and restrict the fl ow of the fl ue gases. Incom-
plete combustion, such as occurs during startup, shut-
down, or incorrect operation of the room heater will lead
to some soot formation which will collect in the exhaust
venting system. The exhaust venting system should be
inspected at least once every year to determine if clean-
ing is necessary.
The venting system may need to be cleaned at least
once a year or more often depending upon the quality
of your fuel or if there is a lot of horizontal pipe sections.
Ash will build up more quickly in the horizontal sections.
May 12, 2014
14. Preparing Firebox for Non-Burn Season
Frequency: At the end of the heating season
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove all ash from the fi rebox and vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
• Use the Touch-Up paint supplied with the appliance;
or,
• Purchase paint from your local dealer.
• Must use a high-temperature paint made specifi -
cially for heating appliances.
7022-122D