6.1.3 Verification result output
(1) Report of match/mismatch status
You can select any of the following report types using the configuration software (ScannerSetting_2D). Selecting
"Disable transmission" reports nothing.
If there is a match:
Disable transmission.
Code data transmission.
OK transmission.
(2) Beeper and indicator LED
You can check whether the verification result is a match or mismatch with the beeper and indicator LED.
When the beeper and indicator LED are enabled, they act as shown below in default setting.
2-point
If there is a match:
If there is a mismatch:
n-point
If there is a match:
If there is a mismatch:
Output of the master data registered
Scanning the "Output master data" code given below lets the scanner output the verification section of master data
entered in the Data verification read procedure, together with the code ID mark.
If there is a mismatch:
Disable transmission.
Code data transmission.
NG transmission.
Beeper
Beeping times
Emits a short 2 beeps.
Emits a long beep.
Emits a short 1 beep.
Emits a long beep.
"Output master data" code
16
Beeping tone
Middle beeping tone
High beeping tone
Middle beeping tone
Middle beeping tone
Indicator LED
Lights in blue.
Flashes in red.
Lights in blue.