Operating your Log Loader in the TrainMaster Command Control
environment
A
fter you have connected the Log Loader to the Command Base and assigned it a unique ID
number, you are ready to operate the accessory. Please note that the Log Loader will
respond only while you are operating the controls.
Begin by addressing the Log Loader. Press ENG and enter the unique ID number assigned in
the previous section.
• Operating the stakes using the red THROTTLE KNOB on your CAB-1 Remote Control. A
clockwise rotation will lower the stakes. A counter-clockwise rotation will raise the stakes.
• Operate the chain drive using the BRAKE and BOOST buttons. BOOST turns on the drive.
BRAKE turns off the drive.
• Turn the lights on and off and adjust the intensity using the F and R buttons.

Restoring the factory default settings

F
ollow these steps to reset the Log Loader to its factory defaults. The ID numbers and voltage
settings will be reset.
Note!
Your recording will not be cleared.
1. Remove the jumper from the underside of the controller. Refer to Figure 5 on page 7 for the
location of the jumper.
2. Turn off power to the Log Loader.
3. Pull the three levers down towards the front of the controller.
4. While holding the three levers down, turn on power to the Log Loader. The LED flashes once.
5. Release the levers. At this point, the LED will flash.
6. Replace the jumper, and the Log Loader is reset.