Table 9. Tasks overview
Task
Accessing the DS4400 Storage
Server components and indicator
lights
Turning on or off the power
Monitoring DS4400 Storage Server
status through software
Checking fault indicator lights for
component failures
Restoring power after a power supply
shutdown
Checking the battery service date
Preparing to move the DS4400
Storage Server
Removing the front bezel to access the DS4000 Storage Server
components
To access the controllers, battery, storage server fan, and indicator lights, you must
remove the DS4400 Storage Server bezel, as shown in Figure 21 on page 23.
22
IBM TotalStorage DS4400 Fibre Channel Storage Server: User's Guide
Description
To access the controller CRUs,
battery, storage server fan, and
indicator lights, remove the DS4400
Storage Server bezel.
The DS4400 Storage Server usually
runs continuously. However, you might
need to turn off the power to move the
DS4400 Storage Server or to perform
maintenance procedures.
Run the storage-management
software continuously. This software
checks the storage subsystem for
failures and displays messages
indicating the types of failures and the
recovery procedures.
Component failures are indicated by
lights on the front and back of the
DS4400 Storage Server and are
monitored by the
storage-management software.
Note: The indicator lights identify
problems with the DS4400 Storage
Server components, but you might
need more information to thoroughly
diagnose and repair the unit.
Therefore, it is important to use the
storage-management software to
continuously monitor the status of the
DS4400 Storage Server.
When the DS4400 Storage Server
shuts down because of a power
supply overtemperature condition,
take special care restarting it.
Periodically check the battery service
date information. Replace the battery
whenever it fails to hold a charge or
every three years.
Note: Using the DS4400 Storage
Server in a hot environment (above
35° C or 95° F), lowers the battery life
expectancy. Environmental conditions
that are not in the specified range is
not supported.
You might need to move the DS4400
Storage Server to a new location or
remove the chassis from its rack
cabinet.
See
"Removing the front bezel to access
the DS4000 Storage Server
components"
"Turning on the power" on page 24
and "Turning off the power" on page
25
"Monitoring status through software"
on page 27
"Checking the indicator lights" on page
27
"Overtemperature condition and power
supply shutdown" on page 36
"Checking the battery service date" on
page 37
"Preparing to move the DS4400
Storage Server" on page 38