Names of Parts on the Front Panel
6-2-3

Using the Keys

Level Key
Mode Key
Up Key
Down Key
Level Key + Mode Key
UNIT Key
CH Key
COPY Key
6-2-4

Main Functions

Display
Settings
Copy
5. UNIT/CH display
Displays the E5ZN Temperature Indicator unit number and channel num-
ber that will be set and displayed on the E5ZN-SDL.
When facing the front panel, the unit number (0 to F) is displayed on the
left and the channel number (1 to 2, U) is displayed on the right.
When the channel number is "U," the setting and display is used by both
channels.
Press this key to select the setting levels.
Press this key to select parameters within each level.
Each press of this key increments values displayed on the No. 2 display. Hold-
ing down this key continuously increments values.
Alternatively, the display moves to the next setting item.
Each press of this key decrements values displayed on the No. 2 display.
Holding down this key continuously decrements values.
Alternatively, the display moves back one setting item.
This key combination sets the E5ZN to the "protect level." For details on the
protect level, refer to 6-3 Setup Level Configuration and Front Panel Keys .
Each press of this key increments the unit number.
Select the E5ZN Temperature Controller unit number to set for the E5ZN-SDL.
Each press of this key changes the channel number.
The channel number cannot be selected when the channel number display for
the E5ZN Temperature Controller is "U" because the setting is used by both
channels.
Press this key to read all E5ZN Temperature Controller set values to the
E5ZN-SDL or to write all set values to the E5ZN from the E5ZN-SDL.
The process value and set values for the E5ZN Temperature Controller as
well as other data and control outputs, auxiliary outputs, and other status
information can be displayed.
The parameters and control operations for the E5ZN Temperature Controller
can be changed.
All settings for the E5ZN Temperature Controller can be read and saved to the
E5ZN-SDL. Also, all the settings for the E5ZN Temperature Controller that
were saved in the E5ZN-SDL can be written to the E5ZN Temperature Con-
troller.