Download Print this page

Changing The Baud Rate - Extron electronics 10 Plus User Manual

Extron switchers user's manual
Hide thumbs Also See for 10 Plus:

Advertisement

Changing the Baud Rate

The RS-232 protocol factory setting is 9600 baud, 8-bits, no
parity, 1 start bit and 1 stop bit. The position of internal rotary
switch SW3 on the main controller board controls the baud
rate and parity. To change the switch setting, remove the four
screws from the top of the case and lift the cover straight up.
Locate SW3 (see drawing below) and use a small, flat blade
screwdriver to rotate the switch to the desired position. SW3
switch positions are defined in the table below.
8-bit, no parity, 1 stop bit
_ Adjust SW3 to set the RS-232 Baud Rate and Protocol.
SW3 Rotary Switch
Page 2-7
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User's Manual
Model 8/10 PLUS Operation and Configuration
0 = 300 baud
1 = 600 baud
2 = 1200 baud
3 = 2400 baud
4 = 4800 baud
5 = 9600 baud
6 = 19200 baud
7 = 38400 baud
8-bit, odd parity, 1 stop bit
8 = 300 baud
9 = 600 baud
A = 1200 baud
B = 2400 baud
C = 4800 baud
D = 9600 baud
E = 19200 baud
F = 38400 baud

Advertisement

loading

This manual is also suitable for:

8 plus