Password Information
]
The
Password:
requires a password (administrator level or user level) followed by a carriage return. The
prompt is repeated if the correct password is not entered.
If the correct password is entered, the unit responds with
]
Login User
both administrator and user, the unit defaults to administrator privileges.
Error Responses
When the PC1 receives a valid SIS command, it executes the command and sends a response
to the host device. If the PC1 is unable to execute the command because the command is
invalid or it contains invalid parameters, it returns an error response to the host.
The error response codes and their descriptions are as follows:
– Invalid port number
E12
E13
– Invalid value (the number is out of range/too large)
– Not valid for this configuration
E14
– System timed out
E17
E22
– Busy
– Privilege violation
E24
E25
– Device is not present
– Maximum number of connections has been exceeded
E26
– Invalid event number
E27
E28
– Bad filename or file not found
– Hardware failure (followed by a colon [
E30
– Attempt to break port pass-through when it was not set
E31
Error Response References
The following superscripted numbers are used within the command descriptions in the
Command and Response table to identify commands that may respond as shown:
14
=
commands that give an
sent to an IPL product whose power configuration does not support the command.
24
=
commands that give an
the administrator level.
=
27
commands that may yield an
28
=
commands that may give an
prompt is displayed only if there is a password defined in the unit. It
]
, depending on the password entered. If the passwords are the same for
(invalid command for this configuration) response if
E14
(privilege violation) response if you are not logged in at
E24
E27
(invalid event number) response.
(file not found) response.
E28
]
Login Administrator
] and a descriptor number)
:
IPL T PC1 • SIS Programming and Control
]
or
48