Serial Port 4 Transmit Clock Configuration (J17) - Motorola MVME2600 series Installation And Use Manual

Single board computer
Hide thumbs Also See for MVME2600 series:
Table of Contents

Advertisement

Hardware Preparation and Installation
1

Serial Port 4 Transmit Clock Configuration (J17)

1-10
In synchronous serial communications, you can configure Serial Port 4 on
the MVME2603/2604 to use the clock signals provided by the TxC signal
line. Header J17 configures port 4 to either drive or receive TxC. The
factory configuration has port 4 set to receive TxC.
To complete the configuration of Serial Port 4, you must set the following
configuration headers as well:
J16 (Serial Port 4 receive clock configuration)
J20 (Serial Port 4 transmit clock receiver buffer control)
J15 on the MVME712M transition module or J3 on the MVME761
transition module (Serial Port 4 clock configuration)
Figure 1-9
and
Figure 1-10
Figure 1-15
(for the MVME761) diagram the overall jumper settings
required on the MVME2603/2604 and transition module for a Serial Port
4 DCE or DTE configuration.
For additional details on the configuration of those headers, refer to
MVME712M Transition Module Preparation on page
Transition Module Preparation on page
manuals for the transition modules (listed in
Documentation) as necessary.
J17
3
2
1
Drive TxC
(for the MVME712M) and
1-25, or to the respective user's
Appendix D, Related
J17
3
2
1
Receive TxC
(factory configuration)
Computer Group Literature Center Web Site
Figure 1-14
and
1-14,
MVME761

Advertisement