Clearance Requirements

Minimum Clearances to
Combustible Materials
Maintain clearance, (empty space), between combus-
tible materials and the heater as specified below.
A
A: To Side Wall / Trim*........................... 4" (10 mm)
ST101
B: To Rear Wall ..................................... 4" (10 mm)
Min. Freestanding Clrnc
Alcove Clearances
4/15/99 djt
B
A: Maximum Alcove Depth .............. 4" (610 mm)
B: To Side Wall .................................. 4" (10 mm)
ST103a
C: To Rear Wall ................................. 4" (10 mm)
Min. Clrnc
11/12/99 djt
D: To Ceiling .................................. 60" (154 mm)
Fig. 2 Minimum wall clearances.
30005056
B
ST101
B
A
C
D
ST103a
Radiance® Vent-Free Gas Heater
V
W
X
Mantel
Ref.
Shelf Depth
A
7¹⁄₂" (190 mm)
B
6"
(15 mm)
C
4¹⁄₂" (114 mm)
D
3"
(75 mm)
E
1¹⁄₂" (38 mm)
Fig. 3 Minimum mantel clearance.
FP599b

Hearth Requirements

JUV
stove mantel heights
The Radiance Unvented heater must be installed on
9/21/00 djt
rigid flooring. If the appliance is installed on any com-
bustible surface other than wood flooring, such as
carpet or tile, a metal or wood panel must be installed
to extend the full length and width of the unit. There are
no other hearth or floor protection requirements.
WARNING
• Do not install this heater in a bathroom or bed-
room.
• Installation of this heater must conform with local
codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
• This heater creates warm air currents. These
currents move heat to wall surfaces next to the
heater. Installing the heater next to vinyl or cloth
wall coverings or operating the heater where im-
purities in the air such as tobacco smoke exist,
may discolor walls.
Do not use a blower insert, heat exchanger
insert or other accessory not approved for use
with this heater.
A
B
C
D
Wall
E
Y
Z
Mantel from
Ref.
Stove Top
V
16"
(406 mm)
W
14¹⁄₂" (368 mm)
X
13"
(330 mm)
Y
11¹⁄₂" (9 mm)
Z
10"
(54 mm)
ST694