Catalytic Combustor - Vermont Castings Radiance 0003380 Homeowner's Installation And Operating Manual

Vent free gas heater
Hide thumbs Also See for Radiance 0003380:
Table of Contents

Advertisement

Catalytic Combustor

The combustor should be cleaned annually to ensure
optimal performance. Follow the procedure below.
Remove the Combustor Module
1. Be sure the heater is COLD.
. Remove the front plate, top grille and screen. (Fig. 35)
3. Use the phillips screwdriver to remove the two sheet
metal screws that secure the combustor to the top of
the firebox. (Fig. 36) Use a flat screwdriver to lift the
unit up and out through the front of the stove.
Clean the Combustor Module
1. Clean the outer surface of the filter with the brush at-
tachment of your vacuum sweeper to remove loose
dirt.
. Submerge the filter in a mild soapy water solution.
Rinse thoroughly with distilled water.
3. Replace in heater when dry.
Replace the Combustor Module
1. Slide the combustor through the front opening of
the stove and insert it into the housing on top of the
firebox. Secure with the two sheet metal screws.
. Replace the glass panel and front.
30005056
Radiance® Vent-Free Gas Heater
Fig. 35 Remove the front plate and top grille/screen.
ST139
Radiance
remove front
4/20/01 djt
Fig. 36 Remove the catalytic combustor module.
ST201
remove catalytic
combustor
11/99
ST139
ST01
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Radiance 0003381

Table of Contents