Rs-485 Full-Duplex 4-Wire Network - KTI Networks KSC-240 Installation Manual

Industrial rs-232 to rs-485/422 converter
Table of Contents

Advertisement

The converter features RS-485 driver and receiver in one device. It also
provides very flexible configuration settings for Driver Enable control
and Receiver Enable control. The configuration for the node in RS-485 2-
wire network is:
SW1-2&1 2W
SW1-4
TXC
SW1-6
RXC
SW1-5
RTS-E
SW2-1
SDE
SW2-2-8 Baud
SW1-3
T-D

3.5 RS-485 Full-duplex 4-wire Network

The 4-wire network simplifies bus arbitration in multi-node RS-485. A
single Master node is the only driver allowed on the top most wire pair.
All other nodes listen to all data traffic that passes on the party-line type
multi-drop bus. Nodes may transmit on the lower pair of wires when
addressed by the master node or by using a software token-passing bus
arbitration scheme.
Select 2-wire topology
Enable RTS/ADC Control for Driver
Enable RTS/ADC Control for Receiver
Use RTS control (optional)
Use ADC control (optional)
Baud when ADC control is enabled (optional)
Disable internal terminator (optional)
-39-

Advertisement

Table of Contents
loading

Table of Contents