Bloomfield 9221EUFC Owner's Manual

Ss2 - series dual satellite coffee brewers with electro-mechanical control and externally heated satellite servers

Advertisement

Quick Links

Model 9221EUFC Dual Satellite Brewer
p/n 76653 Rev. A ECN-12567
671EU
OWNERS MANUAL
for
SS2 - SERIES
DUAL SATELLITE
COFFEE BREWERS
with
ELECTRO-MECHANICAL
CONTROL
and
EXTERNALLY HEATED
SATELLITE SERVERS
MODEL:
9221EUFC
Includes:
Installation
Operation
Use & Care
Servicing Instructions
M671EU 100603 cps

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9221EUFC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bloomfield 9221EUFC

  • Page 1 671EU OWNERS MANUAL SS2 - SERIES DUAL SATELLITE COFFEE BREWERS with ELECTRO-MECHANICAL CONTROL EXTERNALLY HEATED SATELLITE SERVERS MODEL: 9221EUFC Includes: Installation Operation Use & Care Servicing Instructions Model 9221EUFC Dual Satellite Brewer p/n 76653 Rev. A ECN-12567 M671EU 100603 cps...
  • Page 2: Warranty Statement

    The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment are based upon the limitations in this warranty.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Thank You for purchasing this WARRANTY STATEMENT Bloomfield Industries appliance. SPECIFICATIONS Proper installation, professional FEATURES & OPERATING CONTROLS operation and consistent PRECAUTIONS & GENERAL INFORMATION maintenance of this appliance will AGENCY APPROVAL INFORMATION ensure that it gives you the very...
  • Page 4: Features & Operating Controls

    FEATURES AND OPERATING CONTROLS Fig 1. SS-2 Satellite Brewing System Features & Operating Controls...
  • Page 5 FEATURES AND OPERATING CONTROLS (continued) Brewer Adjustable Legs Allows brewer to be leveled. Also allow clearance for cleaning underneath brewer. Brewing Controls Start or stop brew and select brew volume. Right and left section are independent. Heater Switch Turns power to tank heater ON or OFF. Hot Water Faucet Hot water dispensed here.
  • Page 6: Precautions & General Information

    GENERAL INFORMATION AND PRECAUTIONS This appliance is intended for use in commercial establishments WARNING: only. Electric Shock hazard This appliance is intended to brew hot beverage, specifically coffee, for human consumption. No other use is recommended or authorized All servicing requiring access by the manufacturer or its agents.
  • Page 7: Installation

    Plumbing installer must supply the regulator. ADJUST Brewer must be connected to a potable water supply. Bloomfield HEIGHT recommends not less than 1/4” (6 mm) inside diameter copper tubing for installations of 12’ (4 meters) or less, and not less than ATTACH 3/8”...
  • Page 8 INSTALLATION INSTRUCTIONS (continued) EUROPEAN ELECTRICAL INSTALLATION INSTRUCTIONS IMPORTANT ! These installation instructions IMPORTANT ! are prepared for personnel • Make sure the incoming voltage is the same voltage, authorized, qualified, certified or frequency and phase as specified on the appliance licensed to install electrical nameplate.
  • Page 9: Operation

    INSTALLATION INSTRUCTIONS (continued) INITIAL SET-UP INSTRUCTIONS IMPORTANT: Initial set-up must be performed Plumber’s and Electrician’s installation procedures must be by a qualified installer or completed before proceeding with the set-up. qualified service technician. Improper set-up will damage the Be sure all electrical connections are secure, and that all brewer and void the warranty.
  • Page 10 OPERATING INSTRUCTIONS Fig. 3 Control Panel GETTING STARTED Check the brewer and satellites: Check that the brewer is clean and the drip tray (if used) is empty. Check that the satellites are empty and clean with lids properly installed. Check the spray heads: Remove the brew chambers.
  • Page 11 Prepare the Brew Baskets: Make sure the wire rack is properly installed in each brew chamber. Insert one (1) Bloomfield paper filter into each brew chamber. Fig. 5 Brew Basket Make sure the filter is properly supported by the wire rack.
  • Page 12: Cleaning Instructions

    CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer Burn Hazard PRECAUTIONS: Press POWER key to OFF. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns.
  • Page 13 CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite CAUTION: Burn Hazard PRECAUTIONS: Drain Satellite before Cleaning Brewing and serving FREQUENCY: Twice Weekly temperatures of coffee are extremely hot. TOOLS: Sight Glass Brush, Sanitizer Hot coffee will cause Soft Clean Cloth, Bucket serious skin burns. IMPORTANT: 1.
  • Page 14: Servicing Instructions

    SERVICING INSTRUCTIONS CAUTION - PROCEDURE: Delime the Water Tank CHEMICAL BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Deliming chemicals are caustic. Wear appropriate protective FREQUENCY: As required (Brewer slow to heat) gloves and goggles during this procedure.
  • Page 15 Should deliming hoses become necessary, Remove spray disks and gaskets. Rinse both brew heads Bloomfield recommends with clean water. Using a stiff brush, scrub spray disk to replacing the hoses. remove any lime or calcium build-up. Reinstall gaskets and spray disks.
  • Page 16 SERVICING INSTRUCTIONS (continued) CAUTION: TIMER ADJUSTMENT SHOCK HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Disconnect brewer from electric power before opening the FREQUENCY: As required to adjust delivered volume access panel. TOOLS: Phillips head screwdriver Adjustments to be performed by Satellite or other container to calibrate volume qualified technician only.
  • Page 17: Temperature Adjustment

    SERVICING INSTRUCTIONS (continued) CAUTION: TEMPERATURE ADJUSTMENT SHOCK HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Live electrical circuits are exposed during this procedure. FREQUENCY: As required to adjust delivered volume Use care to avoid uninsulated electrical connectors. TOOLS: Phillips head screwdriver Satellite or other container to calibrate volume...
  • Page 18: Troubleshooting Suggestions

    Brew valve damaged Replace brew valve Tank water boiling Adjust or replace thermostat Brew chamber overflows Too many paper filters or wrong Use one genuine Bloomfield filter used. paper filter per brew Chamber discharge hole Clean brew chamber plugged Timer not set properly...
  • Page 19: Satellite Exploded View & Parts List

    SATELLITE EXPLODED VIEW & PARTS LIST SATELLITE MODEL 9440 4.10 PART OF ITEM 4 4 PL 2 PL ITEM PART NO. DESCRIPTION WELDMENT, SATELLITE 83863 TANK LID ASSY 84313 HANDLE / FAUCET GUARD 86577 FAUCET & SHANK ASSY 86600 FAUCET, MODEL ESP 8700-25L SEAT CUP, #3S10 84392 HANDLE, #13SBE-SNAP...
  • Page 20: Brewer Exploded Views & Parts Lists

    EXPLODED VIEW CABINET AND EXTERIOR COMPONENTS...
  • Page 21 PARTS LIST CABINET AND EXTERIOR COMPONENTS ITEM DESCRIPTION ITEM DESCRIPTION WARMER BASE 9012-38 STRAIN RELIEF HOUSING UPPER ASSY 55485 NUT HEX 1/4-20 SS 84382 SWITCH ROCKER HI-TEMP 60310 TERMINAL BLOCK 3P SCREW 8A x 1/2 TR TAP SS BRACKET THERMOSTAT 82533 BREW CHAMBER ASSY (SS) LUG GROUND SOLDERLESS...
  • Page 22 EXPLODED VIEW INTERIOR COMPONENTS...
  • Page 23 PARTS LIST INTERIOR COMPONENTS ITEM DESCRIPTION ITEM DESCRIPTION 83778 RETAINING CLIP TANK LID 84619 VALVE DISPENSING ADJUST NUT KEPS 8-32 SS 82148 LOCK WASHER 8043-12 GASKET TANK COVER 55485 NUT 1/4-20 (pk 100) 8783-1 FAUCET HOT WATER SCREW 8A x 1/2 TR TAP SS BRACKET OUTLET VALVE 86280 THERMOSTAT 15"...
  • Page 24: Wiring Diagram

    WIRING DIAGRAM...
  • Page 25 WATER FLOW DIAGRAM WATER FLOW INLET The 9221-Series of brewers have two The INLET VALVE is controlled by a signal from the CONTROL independent brewing BOARD. If the WATER LEVEL PROBE does not detect water, the systems sharing a inlet solenoid is opened until water is again sensed. common hot water tank.
  • Page 26 Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service Association Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 ( for orders only website: www.wellsbloomfield.com...

Table of Contents