Troubleshooting
8-8
Table 8-1. Alarm Conditions (2 of 4)
Alarm Condition
What It Indicates
LMI Down,
The Local Management
2
frame relay link
Interface is down for the
specified frame relay link.
LMI Down,
The Local Management
2
frame relay link
Interface is down for the
specified frame relay link.
LOS at Network 1
A Loss of Signal (LOS)
condition is detected on the
network interface. Clears
when a signal is detected.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network port, Network 1.
– Port-1. The frame relay link associated with the user data port.
July 2000
Network cable problem.
No signal is being
transmitted at the far-end
FrameSaver unit.
What To Do
For the network interface:
If LMI was never up, verify
that the LMI Protocol setting
reflects the LMI type being
used.
If LMI was never up:
– Verify that the proper time
slots have been configured.
– Verify that the LMI Protocol
setting reflects the LMI type
being used.
Verify that Frame Relay
Performance Statistics show
LMI frames being transmitted.
If all of the above have been
verified and the physical link is
not in Alarm, contact your
network provider.
For user data port:
Check that the DTE cable is
securely attached at both
ends.
Verify that Transmit Clock
Source and Invert Transmit
Clock options are properly
configured.
Verify that Frame Relay
Performance Statistics show
LMI frames being received. If
no frames are being received:
– Check the attached device.
– Verify that the LMI Protocol
setting reflects the LMI type
being used.
Check that the network cable
is securely attached at both
ends.
Check far-end FrameSaver
unit status.