Paradyne FrameSaver DSL 9783 User Manual page 118

Hide thumbs Also See for FrameSaver DSL 9783:
Table of Contents

Advertisement

Operation and Maintenance
6-20
Table 6-9. PVC Connection Status (2 of 2)
Field
Status
EDLCI
0 to 62
Status
Active
Inactive
Disabled
Invalid
1
For the circuit to be active, both Source and Destination Statuses must be Active.
July 2000
What It Indicates
For multiplexed DLCIs only.
Identifies an individual link/
connection embedded within a
DLCI.
Identifies whether the physical
interfaces, LMIs, and DLCIs are all
enabled and active for this PVC
connection.
1
The PVC is currently active.
The PVC is inactive because:
– Alarm conditions and network
and SLV communication
status indicate that data
cannot be successfully
passed.
– The unit has disabled the
interface or frame relay link
due to internal operating
conventions.
– Activation of an alternate
virtual circuit is not warranted;
that is, no alarm condition on
the primary destination link
has been detected.
The PVC cannot be activated
and is essentially disabled as a
result of how the unit was
configured. Possible causes:
– The physical interface at one
or both ends of the PVC is/are
disabled.
– The frame relay link on one or
both ends of the PVC is/are
disabled.
Some portion of the PVC
connection is not fully configured.
9783-A2-GB20-00