FrameSaver DSL 9783 Router Overview

The FrameSaverr DSL (Digital Subscriber Line) 9783 Router is a component in the
FrameSaver system. This system allows you to perform end-to-end service level
management across a hybrid FrameSaver DSL/ATM/Frame Relay network. QoS
(Quality of Service) capabilities of ATM (Asynchronous Transfer Mode) transport
protocol assures quality of service across the network. Service providers can isolate
and correct problems remotely from their NOC (Network Operations Center).
The FrameSaver DSL 9783 Router has an SDSL front end and is a manageable frame
relay aware endpoint. The router operates as a bridge or an IP router connecting a DSL
link to an Ethernet network.
The FrameSaver DSL 9783 Router is available as a:
H
Basic Feature Set 1
H
Advanced SLV (Service Level Verification) Feature Set 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
1
1
6
7
10
10
12
14
15
16
19
19
23
24

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne FrameSaver 9783

  • Page 1: Table Of Contents

    FrameSaverr DSL 9783 Router Installation Instructions Document Number 9783-A2-GN11-00 December 2000 Contents FrameSaver DSL 9783 Router Overview ......Wiring and Cables You May Need .
  • Page 2 Basic FrameSaver DSL 9783 Router The FrameSaver DSL 9783 Router is used for data only and provides corporate LAN access over traditional twisted-pair copper telephone wiring. Copper pairs run from the central office (CO) to the customer premises (CP) to create the local loop. The local loop terminates on the customer premises at the demarcation point in a punchdown block or network interface device (NID).
  • Page 3 The FrameSaver DSL 9783 Router includes: Frame aware diagnostic Feature Set 1 Basic frame relay statistics Interoperability with all existing FrameSaver products Ethernet port for local management Multi-level password protection for three user interfaces: — ASCII terminal management via menu-driven interface —...
  • Page 4 Upgrading a Basic Unit to SLV The FrameSaver DSL 9783 Router can perform full end-to-end SLV when full SLV capability is activated in a basic FrameSaver DSL model. The Advanced SLV Feature Set 2 adds: QoS verification across the network PVC/VC provisioning Multiplexed management PVCs Command activated advanced SLM &...
  • Page 5: Package Checklist

    It also helps us maintain competitive prices for our products. Complete documentation for this product is available at www.paradyne.com. Select Library → Technical Manuals → FrameSaver Frame Relay Devices.
  • Page 6: Wiring And Cables You May Need

    Use an Ethernet shielded twisted-pair CAT5 or better straight-through or crossover cable. Refer to Cables & Connectors on page 20 for standard pin numbers. Contact your sales representative to order cables. Paradyne Port Cable Options Part # COM port with a...
  • Page 7: Installing The Framesaver Dsl 9783 Router

    Installing the FrameSaver DSL 9783 Router Place the FrameSaver DSL 9783 Router on a flat surface with clearance for the rear connectors. " Procedure 1. Use an RJ48C 8-pin or an RJ11 6-pin network interface cable for the DSL connection (cable supplied for U.S. use). Insert one end of the cable into the jack labeled NET.
  • Page 8 3. Use a straight-through cable to connect the other end to an Ethernet hub. (To connect to a hub’s Uplink connection, use an Ethernet crossover cable). DSL 9783 Router ETHERNET P O W C O M E T H E R N E T N E T Ethernet...
  • Page 9 5. Insert the supplied power cord’s round end into the jack labeled POWER. Plug the transformer into an AC outlet. Install the supplied tie wrap. Grounded Power Outlet Wrap Power Jack P O W C O M E T H E R N E T N E T 9783-C...
  • Page 10: Status Leds

    Refer to Troubleshooting for LED indications requiring action. Status LEDs All of the LEDs turn on and off during the power-on self-test. After a successful self-test, the LEDs should appear as indicated in BOLD in the Condition column below. Condition Status System LEDs The DSL router has power.
  • Page 11 LED Symptom Action All LEDs are on. If the LEDs remain on for more than ten minutes, the DSL router is not functional. Unplug the unit and reapply power. If the ALM LED is still on, contact the service provider. ALM LED only The Alarm LED may be on because the power-on self-test remains on.
  • Page 12: Finalizing The Router Configuration Setup

    Finalizing the Router Configuration Setup After the hardware installation, the router can be accessed locally or via Telnet to configure the unit via the User Interface screen and the Command Line Interface. Configuration Roles The FrameSaver DSL 9783 Router has several interfaces that may be provisioned by different groups.
  • Page 13: Main Menu

    Main Menu main 9783-Rtr Device Name: 09/11/2000 00:02 MAIN MENU Status Test Configuration Control Easy Install ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Ctrl-a to access these functions, Shift-r to access the Router’s CLI. Exit Menu Navigation The FrameSaver unit should operate using the default (factory-set) configuration options.
  • Page 14: Verifying That Self-Test Passed

    As an example, follow these steps to go to the Configuration Edit/Display menu so you can start setting up the unit. " Procedure To load a configuration for editing: 1. From the Main Menu, press the Tab key twice or press the down (↓ ) arrow twice so the cursor is on Configuration.
  • Page 15: Using The Framesaver Easy Install Screen

    FrameSaver DSL Easy Install Screen An Easy Install screen is provided for custom configurations, but is not required for normal installation. " Procedure 1. Select the Easy Install feature. Main Menu → Easy Install Easy Install Screen Example main/easy_install 9783-Rtr Device Name: 09/11/2000 00:01 EASY INSTALL...
  • Page 16: Completing Setup From The Noc

    5. If the Ethernet port will be used, select the Ethernet Port Options Screen. You are taken to the Ethernet Port Options input screen. — Interface status: select Enable. — To the prompt Would you like to set the Node’s Default IP Destination to Ethernet?, respond Yes and configure the following: Enter the IP Address and Subnet Mask for the Ethernet interface.
  • Page 17: Configuring Snmp Trap Managers And Traps

    Configuring SNMP Trap Managers and Traps Once the FrameSaver unit is connected to the network, SNMP trap managers and SNMP traps can be configured. " Procedure To enter SNMP managers and configure traps: 1. Select SNMP Traps. Main Menu → Configuration → Management and Communication → SNMP Traps 2.
  • Page 18: Checking Pvc Connections

    Checking That Data is Being Received " Procedure To verify that data is being received: 1. From the FrameSaver DSL 9783 Main Menu, select Status, select Performance Statistics, and then select either interface’s frame relay statistics. Main Menu → Status → Performance Statistics → Frame Relay → Net1-FR1 2.
  • Page 19: Provisioning Data Circuits In Openlane

    Provisioning Data Circuits in OpenLane Use the OpenLane Provision Circuit screen to add new circuits that start at the FrameSaver DSL endpoint and traverse the SCM and ATM line card in the Hotwire GranDSLAM. In addition the default VC sets (from 1 to 4), there is a group of 250 VCs allocated to each line card that can be assigned to any port on the card.
  • Page 20 Cables & Connectors This section is reference information. DSL Network Cabling Cable Network DSL interface connector uses an 8-pin, non-keyed modular plug. Use standard twisted-pair CAT3 8-Pin or better cables. RJ48C Pin # Function 1 – 3 Not used Pin #8 Ring Pin #1 6 –...
  • Page 21: Ethernet Cabling

    Ethernet Cabling The Ethernet interface connector uses an 8-pin, non-keyed modular plug. Use shielded twisted-pair CAT5 or better cables. To connect to an Ethernet hub, use a straight-through cable. 8-Pin Straight-Through Connection Pin # Function Ethernet Cable 10/100BaseT TX D+ 10/100BaseT TX D–...
  • Page 22 COM Port Cabling The following table provides the pin assignments for the FrameSaver unit’s 25-position EIA-232-C COM(munication) port connector. Pin # Signal Direction Shield (GND) — DCE Transmit Data ( TXD ) From DTE ( In ) DCE Receive Data ( RXD ) To DTE ( Out ) DCE Request To Send ( RTS ) From DTE ( In )
  • Page 23: Technical Specifications For Dsl 9783 Router

    Technical Specifications for DSL 9783 Router Item Specification Approvals FCC Part 15 Class A digital device Safety Certifications Refer to equipment’s label for approvals on product Physical Environment Operating temperature 32° F to 122° F ( 0° C to 50° C ) Storage temperature –...
  • Page 24: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
  • Page 25 The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation. CANADA – EMI NOTICE This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
  • Page 26: Government Requirements

    Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections. Notice to Users of the Canadian Telephone Network The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s).
  • Page 27: Document Feedback

    Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.

Table of Contents