Specifications

Environmental specifications

Specification
Temperature range*
Operating
Shipping
Maximum wet bulb temperature
Relative humidity
(noncondensing)**
Operating
Non-operating
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.

Server specifications

Specification
Dimension
Height
Depth
Width
Weight (maximum)
Weight (no drives installed)
Input requirement
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Value
10°C to 35°C (50°F to 95°F)
-40°C to 70°C (-40°F to 158°F)
28°C (82.4°F)
10% to 90%
5% to 95%
Value
17.6 cm (6.94 in)
67.3 cm (26.5 in)
46.3 cm (19.0 in)
47.6 kg (105 lb)
36.3 kg (80 lb)
100–127 VAC
200–240 VAC
50–60 Hz
@ 100 VAC–12A
@ 200 VAC–8A
@100 VAC–1161 W
@200 VAC–1598 W
@100 VAC–3960 BTU
@200 VAC–5450 BTU