*39
ENABLE OPEN/CLOSE REPORT FOR
INSTALLER CODE
*40
OPEN/CLOSE REPORT FOR KEYSWITCH
1=enable; 0=disable
41
*
NORMALLY CLOSED or EOLR (Zones 2-8)
1=N.C.loops; 0=EOLR supervision.
Must be "0" for UL installations.
*42
DIAL TONE PAUSE
0=5 seconds; 1=11 seconds; 2=30 seconds.
Must be "0" UL Installations.
*43
DIAL TONE DETECTION
1=wait for true dial tone; 0=pause, then dial
*44
RING DETECTION COUNT
01-14; 15=answering machine; 00=no detection.
Must be "00" for UL Burglary.
*45
PRIMARY FORMAT
0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed;
3= ADEMCO Express
*46
LOW SPEED FORMAT (Primary)
0= ADEMCO Low Speed; 1=Sescoa/Radionics
*47
SECONDARY FORMAT
0=Low Speed; 1=Contact ID; 2= ADEMCO High Speed;
3= ADEMCO Express
*48
LOW SPEED FORMAT (Sec.)
0= ADEMCO Low Speed; 1=Sescoa/Radionics
*49
CHECKSUM VERIFICATION
1=yes; 0=no
*50
SESCOA/RADIONICS SELECT
1=Sescoa; 0=Radionics
*51
DUAL REPORTING
1=yes; 0=no If used with Spilt Reporting "1" option (1*34),
alarms and alarm restores go to both primary & secondary
numbers, while all other reports go to secondary only. If used
with Split Reporting "2" option, alarms and alarm restores go to
both, open/close and test messages go to secondary only,
while all other reports go to primary.
*52
STANDARD/EXPANDED REPORT FOR PRIMARY
[0 0 0 0 0 0]
Alarm Rstr
0=standard; 1=expanded;
Note: Expanded overrides 4+2 format.
*53
STANDARD/EXPANDED REPORT FOR SECONDARY
[0 0 0 0 0 0]
Alarm Rstr
0=standard; 1=expanded;
*54
*57
ALARM REPORT CODES & ID DIGITS FOR
ZONES 01-16.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
[0]
1=enable; 0=disable
[0]
[1]
[0]
[1]
[00]
[1]
[0]
[1]
[0]
[0] [0]
Prim
[0]
[0]
Byp
Trbl
O/C LoBat
Byp
Trbl
O/C LoBat
*58
SUPERVISORY AND RESTORE CODES FOR ZONES
01-16.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
*59
*62
ALARM REPORT CODES & ID DIGITS FOR
ZONES 17-32.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
*63
SUPERVISORY AND RESTORE CODES FOR ZONES
17-32.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
*64
*67
ALARM REPORT CODES & ID DIGITS FOR
ZONES 33-48.
Skip these fields. Use #93 Menu Mode, Zone
|
Programming to program the report codes.
*68
SUPERVISORY AND RESTORE CODES FOR ZONES
33-48.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
*69
*72
ALARM REPORT CODES & ID DIGITS FOR
ZONES 49-64.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
*73
SUPERVISORY AND RESTORE CODES FOR ZONES
49-64.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
*74
*77
ALARM REPORT CODES & ID DIGITS FOR
ZONES 81-99.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
Sec
*78
SUPERVISORY AND RESTORE CODES FOR ZONES
81-99.
Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]
ZONE TYPE RESTORE ENABLES
*
79
FOR ZONE TYPES 1-8
1
2
3
1=enable; [0=disable]
*80
FOR TYPES 9, and 10
1=enable; [0=disable]
– 6 –
|
|
|
Alarm Rst
Trbl
Trbl Rst
|
|
|
Alarm Rst
Trbl
Trbl Rst
|
|
|
Alarm Rst
Trbl
Trbl Rst
|
|
|
Alarm Rst
Trbl
Trbl Rst
|
|
|
Alarm Rst
Trbl
Trbl Rst
4
5
6
7
8
|
|
Byp
Byp Rst
|
|
Byp
Byp Rst
|
|
Byp
Byp Rst
|
|
Byp
Byp Rst
|
|
Byp
Byp Rst
9
10