PROMPT
02 START: PARTN
ANY PARTITION
0
Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not de-
activate the relay.
PROMPT
02 STOP: ZN LIST
0
02 STOP: ZN TYPE
NO RESPONSE
00
02 STOP: PARTN
ANY PARTITION
0
02 RELAY GROUP
0
02 RESTRICTION
1=YES
0=NO
0
02 RELAY TYPE
ECP
1
02 ECP ADDRESS
00
02 MODULE RELAY#
0
02 HOUSE CODE
A
00
02 UNIT CODE
00
When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.
EXPLANATION
If the starting event will be limited to occurring on a specific partition, enter the partition number (1-8) in
which the start event will occur. Enter 0 for any partition.
Press [✱] to continue.
EXPLANATION
If a zone list is being used to stop this relay action, enter the zone list number, 1-8. The restore of a zone
on the zone list stops the relay. If a zone list is not being used, enter 0.
Press [✱] to continue.
If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the
Choices for Start/Stop System Operation chart.
Press [✱] to continue.
This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-8 for specific
partition number.
Press [✱] to continue.
Relays may be grouped for common activation by time-driven events (commands 06-10). Enter 0 (no group)
or 1-8 for a specific group number.
Press [✱] to continue.
The system may have some devices that are not intended to be under end user control, such as relays
activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay group.
Press [✱] to continue.
Enter 1 for (ECP) relay modules (4204). Enter 2 for X-10 devices.
Press [✱] to continue.
If you selected 1 (4204), enter the actual module's address (01-15) as set by its DIP switches.
Press [✱] to continue.
Enter the specific relay number on that module (1-4).
Press [✱] to continue.
The keypad will display the Start and Stop summary screens again.
Press [✱] to continue.
If you selected 2 for X-10 devices, enter the numerical equivalent of the House Code of the device, as
follows:
A=00
D=03
B=01
E=04
C=02
F=05
Enter the numerical unit code of the X-10 device (00-15).
Press [✱] to continue.
The keypad displays the Start and Stop summary screens again.
Press [✱] to continue.
G=06
J=09
H=07
K=10
I=08
L=11
– 27 –
M=12
P=15
N=13
O=14

Hide quick links: