Zone Programming

If using 5800 Series transmitters, do not the install batteries until you are ready to enroll them. After enrolling
the transmitter, the battery need not be removed. This is to prevent enrolling the wrong serial number.
PROMPT
ZONE PROG?
1 = YES
0 = NO
0
SET TO CONFIRM?
1 = YES
0 = NO
0
ENTER ZONE NO.
00 = QUIT
10
Ä
Zone 10 entered ↑
10 ZT P RC
In L
0 0 1 1 0 0 0 1
10 ZONE TYPE
PERIMETER
03
Zone number 10 and Zone
Type 03 entry shown
† These are special zone
types used with 5800
Series Wireless
Pushbutton Units that
result in arming the system
in the STAY or AWAY
mode, or disarming the
system, depending on the
selection made.
10 Partition
1
10 REPORT CODE
1st 03 2nd 12
3C
EXPLANATION
Press 1 to enter ZONE PROGRAMMING mode. The following screens appear. Press [✱] to display the next
screen. Press # to display a previous screen.
This prompt appears once upon entering Zone Programming Mode.
If "Yes," Confirmation prompts will be displayed after the device's Serial and Loop numbers have been
entered later.
Enter the 2-digit zone number to be programmed, as follows:
Protection Zones = 01–86
System Supervisory Zones = 88, 89, 90, 91, 92 (duress), 97 and 98 (bell supervision)
Keypad Panic Zones = 95, 96, 99
Press [✱] to continue.
This display appears, showing a summary of the zone's current programming. ZT = Zone Type, P =
Partition, RC = Report Code, In = the input type of device, and L = the device's loop number to which the
sensor is connected.
Some devices can support more than one zone by means of individual loops (for example, 5801, 5804,
5816, 5817, etc.). If the zone is not programmed, the display appears as shown here. If you are checking a
zone's programming, and it is programmed satisfactorily, press [#] to back up one step and enter another
zone number, if desired.
Press [✱] to continue.
Each zone must be assigned a zone type, which defines the way in which the system responds to faults in
that zone. Refer to the Zone Type Definitions section in the ADEMCO VISTA-50P/VISTA-50PUL Installation
and Setup Guide for detailed definitions of each zone type. Enter the zone type desired (or change it, if
necessary). Available zone types are listed below.
00 = Assign for Unused Zones
01 = Entry/Exit #1, Burglary
02 = Entry/Exit #2, Burglary
03 = Perimeter, Burglary
04 = Interior Follower, Burglary
05 = Trouble Day/Alarm Night
06 = 24 Hr. Silent Alarm
07 = 24 Hr. Audible Alarm
Press [✱] to continue.
Enter the partition number (1–8) you are assigning this zone to.
Press [✱] to continue.
Enter the report code. The report code consists of 2 hexadecimal digits, each in turn consisting of 2
numerical digits. For example, for a report code of "3C," enter 03 for "3" and 12 for "C."
(Refer to the System Communication section in the Installation and Setup Guide for more information about
report codes and reporting formats.)
Press [✱] to continue.
08 = 24 Hr. Auxiliary
09 = Fire Without Verification
10 = Interior Delay, Burglary
20 = Arm–STAY†
21 = Arm AWAY†
22 = Disarm†
23 = No Alarm Response
(e.g., relay activation)
– 13 –