TEMPERATURE GAUGE MOUNTING
Mount the temperature gauge where it is clearly visible to the operator. Attach the
green ( - ) wire from the negative post on the gauge to a grounded bolt on the tractor
frame. Remove paint if needed to make a good ground.
Remove the pipe plug from the side of the hydraulic reservoir, and install the
temperature sensor using thread sealing tape.
Run the white wire from the ( S ) sensor post of the gauge to the temperature sensor
on the hydraulic reservoir tank.