Troubleshooting Guide
In this section we discuss the basic problems that can occur when using
your Bridge/Router Module. If a problem continues to occur, contact your
supplier for assistance.
Management Problems
Can not access the Bridge/Router Module's Management System
Ensure that the terminal is VT100 specification compliant.
Ensure that the communication setting are:- 9600 bits/s, 8 data bits, 1
stop bit, no parity with flow control set up to None or Optional.
If connecting directly to the management port, ensure that the cable
pin specifications are correctly wired as described in
The [Arrow] keys do not work correctly when trying to select a
Menu item from the Bridge/Router Module's MMI.
If using the Windows terminal emulator, ensure that the Use function,
Arrow and [Ctrl] Keys for Windows checkbox is not crossed.